Cooling moulds
The float flow meter is the most common type of flow meter in mould cooling. It is also called a rotameter or variable area flow meter, and the reason for the name becomes clear when you look at how it works: inside there is just a float that rises and falls with the water.
If you are not yet sure what a flow meter is in general, start with What is a flow meter and what is it used for.
A float flow meter consists of a vertical tube that widens towards the top and a float that is free to move inside it. Water enters from the bottom and leaves from the top.
The more water flows, the higher the float stops. That is why it is called variable area: depending on the flow rate, the free space between the float and the tube walls changes.
Next to the tube there is a numbered graduated scale. The reading is taken at the centre of the float: you check which number on the scale it reaches.
In Flowise regulators the scale is the same for all floats. What changes is the flow rate corresponding to each number, because it depends on the float fitted. That is why each float has its own reference sticker, which shows the flow rate in litres per minute (L/min) for each number on the scale.
In practice: read the number reached by the centre of the float and check on the sticker how many L/min it corresponds to.
The advantage over a display is that the reading is immediate and visible from a distance: on a regulator with several circuits you can see at a glance if one float is lower than the others, meaning that a circuit is receiving less water.
With the same tube, the measuring range depends on the weight of the float. A light float rises even with little water and suits low flow rates; a heavy one needs more water to rise and suits high flow rates.
In Flowise water flow regulators the floats are interchangeable, in four versions:
| Model | Measuring range | Float |
|---|---|---|
| 035 | 0 – 3.5 L/min | grey PVC |
| 008 | 0 – 8 L/min | red anodised aluminium |
| 115 | 1 – 15 L/min | brass (type 1) |
| 425 | 4 – 25 L/min | brass (type 2) |
As a rule of thumb, choose the range in which the working flow rate of the circuit falls towards the middle of the scale: the reading is more precise and there is room to see both drops and increases. To estimate the right flow rate for each circuit, see Why measure water flow rate in mould cooling.
For the float to be visible, the body of the flow meter must be transparent. Flowise machines it from a solid block of methacrylate (PMMA), with no glued parts, and tests every regulator at 20 bar with water at 20 °C after assembly.
The operating limits are:
The transparent body also has a practical advantage: you can see straight away if the water is dirty or if there is limescale, and clean it before the float gets stuck.
The float flow meter works by gravity, so a few rules must be followed:
Advantages:
Limits:
When data logging and alarms connected to the press are needed, an electronic flow meter is the option to consider: the full comparison is in Float or electronic flow meter: which one to choose.
On its own, a float flow meter measures the flow rate. In mould cooling you usually also need to adjust it circuit by circuit: that is why Flowise flow meters are built into water flow regulators with supply and return manifolds and brass regulating valves. On each zone you read the flow rate and correct it with the valve.
Six series are available: 5 Serie, 2 Serie, 1 Serie, 1M Serie, 1R Serie and Mini.
There is none: they are two names for the same instrument, also called a variable area flow meter.
No. It works thanks to the weight of the float, so it must be installed vertically with the water entering from the bottom.
Choose the float so that the normal flow rate of the circuit falls towards the middle of the scale. In Flowise regulators the ranges go from 0–3.5 to 4–25 L/min.
Usually because of dirt or limescale in the tube, or because the circuit is closed or clogged. Cleaning the body and the float solves it in most cases.
Yes, in Flowise regulators the floats are interchangeable and the graduated scale stays the same. Just fit the new float with its reference sticker, which shows the flow rate for each number on the scale.
At the centre of the float: check which number on the scale it reaches and read the corresponding flow rate on the reference sticker.
Want to know which float you need for your moulds? Write to us with the number of circuits and the flow rates: we will recommend the right configuration.