Cooling moulds
Two families of instruments are used to monitor the cooling water of a mould: the float flow meter (or rotameter), which is read visually, and the electronic flow meter, which turns the flow rate into a signal. They do the same job in very different ways, and the choice depends on what you need: to see the flow rate, or to record it and have a machine check it.
If you have not yet read how a rotameter works, start with Float flow meter (rotameter): how it works.
Float flow meter. A float rises inside a transparent tube that widens towards the top and stops where the thrust of the water and its weight are in balance. The flow rate is read on a graduated scale. It has no electrical components.
Electronic flow meter. A sensor measures the flow rate and turns it into an electrical signal, which is read on a display or sent to the control of the press or the temperature control unit. The types most used with water are:
For an overview of all types, see What is a flow meter and what is it used for.
| Float flow meter | Electronic flow meter | |
|---|---|---|
| Reading | visual, on the graduated scale | display or signal to the machine control |
| Power supply | not needed | needed (usually 24 V) |
| Data logging | no | yes, if connected to a PLC or supervisory system |
| Alarms | no, the operator has to look | yes, minimum and maximum thresholds |
| Mounting | vertical only | usually any position |
| Dirt and limescale | visible through the transparent body | not visible; they can distort the measurement (especially in turbine models) |
| Maintenance | cleaning of the body and float | cleaning, checking of contacts and calibration |
| Cost per circuit | low | higher, plus cables, PLC inputs and configuration |
| Overview | immediate: all circuits side by side | depends on how the data is displayed |
The rotameter is the most common choice in mould cooling, and it is enough when:
On a regulator with 6, 12 or 24 ways, the floats side by side become a small control panel: a float lower than the others immediately shows a clogged circuit or a closed valve.
An electronic flow meter becomes necessary when:
The practical limit is that the sensor measures, but does not show at a glance what is happening in the tube: if the reading changes you have to find out why, while in a rotameter dirt and air bubbles can be seen directly.
Many moulders use both:
This keeps costs down and keeps the immediate reading on every circuit, without giving up automatic control where the risk of rejects is highest.
To estimate the right flow rate for each circuit, see Why measure water flow rate in mould cooling.
Both the rotameter and the electronic sensor measure the flow rate. To regulate it circuit by circuit you need a valve on each way. Flowise water flow regulators combine the two: supply and return manifolds, a float flow meter and a brass regulating valve on each way, in a body machined from solid methacrylate and pressure-tested at 20 bar.
Six series are available: 5 Serie, 2 Serie, 1 Serie, 1M Serie, 1R Serie and Mini.
Usually yes, but in mould cooling the main need is to spot flow drops in time: that is why the accuracy of a correctly sized rotameter is enough in most cases.
Yes, in everyday language "digital" means an electronic flow meter with a display or a signal output.
No, it needs a power supply, usually 24 V. A float flow meter, on the other hand, works with the water flow alone.
Generally yes, on the supply or return line upstream or downstream of the regulator. Check connections and pressure drop with the sensor supplier.
Electromagnetic and vortex meters have no moving parts and are less sensitive to dirt; turbine meters cost less but must be protected by a filter.
Not on its own. Rotameters with a threshold contact exist, but in mould cooling an electronic sensor on the line is usually used for the alarm.
Not sure whether a rotameter is enough for you? Write to us with the number of circuits, the flow rates and the type of production: we will help you choose the right configuration.