Why measure water flow rate in mould cooling

In injection moulding, cooling is often the longest phase of the cycle: the part cannot be ejected until it has solidified evenly. Yet in many moulding shops the water flow rate in the mould circuits is still set “by eye”, opening the valves and hoping it is enough.

Measuring the flow rate of each circuit with a flow meter changes things: better cooling, fewer rejects and more consistent cycles.

1. Cooling only works with turbulent flow

When water moves slowly through a channel it flows in parallel layers: this is laminar flow. The layer touching the mould wall heats up but mixes little with the rest of the water, so heat transfer is poor.

Above a certain speed the water starts moving in a disordered way, with eddies that keep mixing it: this is turbulent flow. Cold water continuously reaches the channel wall and carries away much more heat.

Laminar vs turbulent flow: the Reynolds number

To know which regime the water is in, you use the Reynolds number (Re):

Re = water velocity × channel diameter / kinematic viscosity

  • Re below 2,300: laminar flow
  • Re between 2,300 and 4,000: transition, unstable
  • Re above 4,000: turbulent flow

In mould cooling many process engineers aim for about Re 10,000, to have a safety margin and effective heat transfer.

Table: minimum flow rate by channel diameter

Flow rate in litres per minute to reach Re 4,000 (minimum turbulent) and Re 10,000 (recommended value):

Channel diameterWater 20 °C — minimumWater 20 °C — recommendedWater 40 °C — minimumWater 40 °C — recommended
6 mm1.1 L/min2.8 L/min0.7 L/min1.9 L/min
8 mm1.5 L/min3.8 L/min1.0 L/min2.5 L/min
10 mm1.9 L/min4.7 L/min1.2 L/min3.1 L/min
12 mm2.3 L/min5.7 L/min1.5 L/min3.7 L/min
14 mm2.6 L/min6.6 L/min1.7 L/min4.3 L/min
16 mm3.0 L/min7.6 L/min2.0 L/min5.0 L/min

How it is calculated: Flow rate (L/min) = Re × ν × π × d / 4 × 60,000, where d is the diameter in metres and ν the kinematic viscosity of water (about 0.000001 m²/s at 20 °C, 0.00000066 m²/s at 40 °C).
Example: 10 mm channel, water at 20 °C, Re 10,000 → 10,000 × 0.000001 × 3.14 × 0.010 / 4 × 60,000 ≈ 4.7 L/min.

Two things to keep in mind:

  • warmer water has lower viscosity and reaches turbulent flow sooner;
  • the narrowest section of the circuit is what counts: do the calculation on the minimum diameter.

These are theoretical values for straight channels: bends, fittings and circuit length increase pressure losses. That is why the flow rate must be measured on the real circuit, not just calculated.

2. Circuits do not balance themselves

In a mould with several circuits fed by the same manifold, water is distributed according to the resistance of each circuit: short, wide circuits get a lot, long ones or those with many bends get little. Opening all the valves fully does not solve the problem, it hides it.

With a flow meter on each zone you immediately see which circuit is starved. With a water flow regulator, which combines measurement and a regulating valve, you bring it back to the correct flow rate at the same point, zone by zone.

Flowise water flow regulator with flow rate and temperature reading on each mould zone

3. Circuits clog without warning

Limescale, rust, residues and impurities build up over time in the mould channels and fittings. The flow rate drops gradually, day after day, without anyone noticing, until parts start coming out warped.

Checking the flow rate regularly lets you spot the drop early and clean the circuit before it becomes a production problem.

4. Part quality and cycle time

Uneven cooling creates internal stresses in the part, which lead to:

  • warpage and distortion;
  • uneven shrinkage and dimensions out of tolerance;
  • surface marks and cosmetic defects;
  • longer cycles, because cooling time is extended to compensate for the hottest zone.

Bringing each circuit to the correct flow rate often makes it possible to reduce cycle time with the same quality.

5. Repeatability at every mould change

When a mould runs well, it is worth noting the flow rate of each circuit. At the next set-up you just restore the same flow rates to get the same process conditions, without starting from scratch.

6. Check the temperature too

Flow rate tells you how much water is passing; temperature tells you how much heat it has carried away. Reading both on each zone shows straight away which circuit is working hardest and which is undersized. That is why Flowise water flow regulators show both flow rate and water temperature on every zone.

Frequently asked questions

How many litres per minute does a mould need for cooling?

It depends on channel diameter and water temperature. For a 10 mm channel with water at 20 °C you need at least about 1.9 L/min for turbulent flow and about 4.7 L/min for the recommended value.

What is the Reynolds number?

It is a number that tells whether water flows in a laminar way (below 2,300) or a turbulent way (above 4,000). In mould cooling the target is turbulent flow.

Does more water always mean better cooling?

No. Once turbulent flow is reached the improvement is smaller, while consumption and pressure losses increase. What matters is that every circuit reaches the correct flow rate.

Why does one circuit get less water than the others?

Because it is longer, has more bends, a smaller diameter or is getting clogged. Without a flow meter on each zone the difference cannot be seen.


Want to balance the cooling circuits of your moulds? Discover Flowise water flow regulators or request an offer.